Return to the Home Page

APDL Seismic Analysis

A tool that builds ANSYS APDL input for the seismic analysis of equipment from a Workbench model file (.dat).
It reads the model, writes the modal and response spectrum commands from a few settings and runs ANSYS in batch mode.
The X, Y and Z results are combined by SRSS and stored in numbered result sets for the qualification report.

Download

Calculation Steps

01

See Details

Model Loading
(Workbench .dat)

Counts the nodes and elements in the NBLOCK and EBLOCK of the .dat file. The BCS component, unit system and element types are shown in the status window. The analysis part of the file is removed before ANSYS is called.

02

See Details

Modal Analysis
(Block Lanczos)

Writes the modal APDL code from the number of modes, the constraint at BCS and the Block Lanczos solver. The natural frequencies and mode shapes are shown after the run. The governing mode and effective mass of each direction are read from the output.

03

See Details

Response Spectrum
(SRSS / CQC)

Writes the freq and sv commands from the RRS pasted from Excel and the damping ratio. The vertical direction uses the V table and the other two use the H table. The ZPA is added as missing mass.

04

See Details

Load Combination
(X, Y, Z Sets)

Combines the X, Y and Z spectrum results by the square root of the sum of squares. The set number of each direction and of the combined result is shown on screen. The sets are read in POST1 for the stress and displacement checks.

How to Use it?

01

Choose the vertical (gravity) direction X, Y or Z. It sets the plot view and decides which axis uses the vertical RRS.

02

Press Load and select the Workbench .dat file. Check the nodes, elements, BCS component, unit system and element types in the status window.

03

Tick the analyses to run, modal analysis and response spectrum analysis. Each tick opens its own tab.

04

In the modal tab, enter the number of modes, choose the constraint and Block Lanczos, then press Run. The frequencies, mode shapes and effective mass are shown.

05

In the spectrum tab, enter the damping ratio, choose SRSS or CQC and paste the H and V RRS from Excel with Ctrl+V.

06

Press Run for the spectrum analysis. The result set numbers of X, Y, Z and the combined SRSS are shown, and Open Folder shows the output files.