Return to the Modal to Word Page

1. Text Parsing

Direction Blocks

Mode Rows

where
  block(d) : text block of direction d
  d : excitation direction (X, Y, Z)
  n fields : number of fields in a row
  t 0 … t 7 : fields of a mode row
  n, f, ratio, M e , % : mode number, frequency, ratio, effective mass, mass percentage


The ANSYS Participation Factor output is split into a separate block for each direction, and each row holds the mode number, frequency, effective mass and so on.
The program separates the direction blocks and reads only the Mode rows into a table.
This allows the same mode to be compared side by side across directions.

2. Governing Mode

Largest Ratio

Sum Row

where
  k * d : dominant mode of direction d
  RATIOk, d : participation ratio of mode k in direction d
  Γk, d : participation factor of mode k in direction d
  M e, k : effective mass of mode k
  ΣM e , Σ% : total effective mass and cumulative mass ratio


In each direction, the mode with the largest effective mass governs the seismic response.
The program marks the mode with the largest Ratio (effective mass ratio) as dominant and uses the total row to check that the cumulative effective mass is sufficient.
In seismic analysis, enough modes are usually included to reach at least 90 % cumulative effective mass.

3. Mode Selection

Main Modes

Range Options

where
  S : set of modes shown in the table
  k * X , k * Y , k * Z : dominant modes of each direction
  N : total number of modes
  ℛ : range option (none, 1–6, 1–10 or all)


Putting every mode in the report makes the table too long, so only the meaningful modes should be chosen.
The program includes the first modes and the dominant mode of each direction by default, and the range option adjusts the count.
As a result, no mode the reviewer needs to see is left out.

4. Word Table

Table Layout

Format Rules

Tables in a calculation report are easier to review when their format is consistent.
The program builds the frequency, directional Ratio and effective mass columns in a fixed order, shows dominant modes in bold and keeps numbers to the same number of digits.
When the analysis results change, a table in the same format can be produced again right away.

Return to the Modal to Word Page
EXAMPLE 2

Heavy Payload Example

This example adds a 220 kg relay rack to the top of the same steel cabinet (632 kg in total) and pastes the new participation text with the 5 column and 10th + main options. The first two modes drop from 17.77 and 22.49 Hz to 10.57 and 12.59 Hz, closer to the peak of the horizontal RRS (3 % damping, 0.5 to 50 Hz), and the vertical governing mode 13 drops from 219.6 to 152.7 Hz. The table lists modes 1 to 10, mode 13 and mode 20 with the sum row, and the governing masses of 474.4 kg (X), 464.3 kg (Y) and 360.7 kg (Z) are shown in bold.

Return to the Modal to Word Page